Lubrication Procedure
EGAS™ and DGAS™ Pumps
Repeat the following procedure twice each time you lubricate
- Make sure both the Top Fill and Bottom Release valves are fully closed
- Slowly remove the 2” Black Plug
- Slowly open the Top Fill Valve fully
- Fill the Swage Nipple with WD40 (try not to get any in the Top Fill valve ball as it may spray out the next time you open it)
- Close the Top Fill Valve
- Replace the 2” Black Plug and tighten
- Slightly crack open the Bottom Release valve and leave it cracked open for a few minutes while the WD40 is sucked into the compressor intake lines (by cracking it open it will slow release, lubricating both sides of the compressor)
- After a minutes close the Bottom Release valve
- Repeat the above procedure to fully lubricate the compressor seals
- Carry out the lubrication process on a weekly basis.